Minisart® RC4 Syringe Filter 17822----------Q, 0.45 µm Regenerated Cellulose
Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 – 14 and is stable against DMSO. Type 17822 with a pore size of 0.45 µm can be used for sample preparation and has a male luer slip outlet. Version Q is a non-sterile bulk pack. Units can be sterilized by autoclaving or EO.
Overview
Non-sterile Minisart® RC syringe filters are supplied in bulk packs. This reduces waste and makes the handling easier whenever the application allows clarification under non-sterile conditions, like this is the case for the majority of sample preparation steps prior to HPLC or GC analysis. The RC membrane is the best option for reliable and leachable free filtration. The very low non-specific binding characteristics of this membrane makes it a perfect choice for aqueous samples and solvents. In addition, unlike PVDF filters, those with RC membranes are suitable for DMSO and other amides, or for ketones, esters, and ethers. The housing of the filter is made of PP (polypropylene) which is compatibility with harsh solvents, acids and bases.
- Bulk packs for less waste
- Minimum extractables or leachables
- Very low non-specific binding
- Outperforming chemical compatibility
Specifications
Applications
- Application Area
- Analytical Sample Preparation
- Clarification
Compliance Information
- BiosafetyAll materials of this filter element meet the requirements of the current USP Biological Reactivity tests for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
- CytotoxicityAccording to ISO 10993-5
Dimensions
- Filter Diameter⌀ 4 mm
- Filtration Area0.1 cm²
- Housing Dimensions12 × 20 mm
General Specifications
- Flow Rate1.5 mL/min with water at 1 bar (14.5 psi) | 3 mL/min with methanol at 1 bar (14.5 psi)
- Total ThroughputUp to 1 mL
- pH Range3.0 – 14.0
Materials of Construction
- Housing MaterialPolypropylene (PP)
Operating Conditions
- Maximum Allowable Working Temperature121 °C (250 °F)
- Maximum Operating Pressure4.5 bar (65 psi)
- Operating Pressure4.5 bar (65 psi)
Physicochemical Information
- Bubble PointMin. value with water 2.0 bar (29 psi)
- Burst PressureMin. value 7.0 bar (102 psi)
- Pore Size0.45 µm
Product Information
- Pack Size500
- PackagingBulk pouch packed
Usage Protocols
- Sterilization Procedures
- Ethylene oxide
- Gamma irradiation
- Autoclave, 121°C, 30 min
Volumes
- Hold-up Volume5 – 10 µL before bubble point